Image1
BEAUTY SLIM UP®   BODY DESIGNER New generation
device for
the treatment
of body
imperfections!

Technical details

Hand-Piece A

µShock Wave (US modulating 21/42Hz)New type of emission able to create a massage through the emission of inelastic energizing waves. The technology is steered in order to emit an energizing wave of mechanical nature, by thus generating some vibrations that spread in all the subcutaneous structures. This technology is mainly applied in the fibrosis and therefore in all problems due to the tissue acidification. The action of protein structures reorganization and the normalisation of the extracellular ambience contribute to the microcirculation improvement with consequent greater uptake of oxygen and local metabolism. Through the parameter setting it is possible to have different action depths and different types of stimulation.

Hyperthermic RF (Six-pole Resistive RF 400KHz)
Special resistive emission able to reactivate the cells designated to the production of elasticising proteins; besides, this energy is able to grant chemical actions on the existing collagen by restoring the lost elasticity. The energy provokes a pleasant heat controlled in the temperature always respectful of all basal structures of derma. Physiologically, the temperature increase entails an increase of tissue oxygenation and therefore an improvement of all cellular and trophic functions. This effect has got a strong benefit in the cellulite treatment. Besides, the controlled increase of temperature leads to the activation of a series of replies, mediated by special cellular receptors, aimed at the increase of the protein synthesis of new collagen.

Athermal RF (Six-pole Resistive 350KHz, modulating 42Hz)
The electromagnetic diathermy, if used in athermal mode, is able to grant a regulatory activity of the proteins of the cellular membrane, by creating ions controlled flows that activate a fall of draining reactions. The radiofrequency signal is remodulated by making it able to interact with different cellular structures.

Press (Max 150Kp)
Phase of treatment that exploits the air mechanical skills. Through pressure rhythmical actions it is possible to stimulate special nervous corpuscles, at derma level, and also at muscular level, responsible of the activation of a firming effect, by thus carrying out a double firming phase both of the skin and of the striated tissue. The treatment is made with different on and off times, according to the application needs of the specific treatment: type 1: T. on 1sec; T. off 1sec;type 2: T. on 1sec; T. off 2sec.

Cavitation (Frequency 37,5Khz, modulating 8 Hz) [ THIS FUNCTION CAN BE USED ONLY ABROAD ITALY ]
This technology uses low frequency ultrasounds for a deep treatment of cellulite problems. The preset programs exploit the multifactorial nature of treatment typical of the device, therefore this technology is available exclusively in the manual program of hand-piece A.




Hand-Piece B

Hyperthermic RF (Six-pole Resistive RF 400KHz) Special resistive emission able to reactivate the cells designated to the production of elasticising proteins; besides, this energy is able to grant chemical actions on the existing collagen by restoring the lost elasticity. The energy provokes a pleasant heat controlled in the temperature always respectful of all basal structures of derma. Physiologically, the temperature increase entails an increase of tissue oxygenation and therefore an improvement of all cellular and trophic functions. This effect has got a strong benefit in the cellulite treatment. Besides, the controlled increase of temperature leads to the activation of a series of replies, mediated by special cellular receptors, aimed at the increase of the protein synthesis of new collagen.

Athermal RF (Six-pole Resistive RF 350KHz, modulating 42Hz)
The electromagnetic diathermy, if used in athermal mode, is able to grant a regulatory activity of the proteins of the cellular membrane, by creating ions controlled flows that activate a fall of draining reactions. The radiofrequency signal is remodulated by making it able to interact with different cellular structures.

Pulsed Vacuum (max 40Kp)
Phase of treatment that exploits the air mechanical skills. Through phases of controlled suction it is possible to act in a selective way on the tissues; the massage, by acting on the reticular fibres, is able to stimulate the tissue regeneration; besides, through the depression phases it is also possible to make an action of skin liquids handling and therefore a draining phase. The treatment is made with different on and off times, according to the application needs of the specific treatment: type 1: T. on 1sec; T. off 1sec; type 2: T. on 2sec; T. off 0,5sec; type 3: T. on 2sec; T. off 4sec.

Electrical Stimulation (Frequency 100KHz, modulating 15Hz)
At the center of the hand-piece there are two microprismatic rolls for the emission of specific currents aimed at the conveyance of the used cosmetic products; these rolls have also the function to improve the hand-piece sliding on the body and apply a direct mechanical action on the treated area.





Active program light Slim UP® Body Designer.


Nand-piece B system with replaceable
filter for vacuum program.










Technical specifications
Input voltage: 230 V~ Main frequency: 47/63 Hz Power consumption: 200 W Electrical safety Class I Applied accessories type BF Continuous operating device Dimensions: 55x64x185 cm

The manufacturer reserves the right to make modification to products to improve them, without giving prior notice.